ATP bioluminescence testing for water systems

Rapid ATP bioluminescence testing for RO plants, dialysis loops, storage tanks and food-processing water: a reading in minutes that shows biological contamination and biofilm before it becomes a lab failure or a fouled membrane.

EDI electrodeionization system producing lab-grade water
Lab-grade water system where ATP testing is used
RO pressure vessel racks inside a Mai Fina container
RO vessel racks with sampling points

What ATP testing is

Adenosine triphosphate (ATP) is present in all living cells. A swab or water sample is mixed with a luciferase reagent and the light produced is read by a luminometer in relative light units (RLU): the more light, the more biological material.

Where we use it

RO feed, after carbon and cartridge filters, RO concentrate and permeate, dialysis distribution loops, product water tanks, filling lines and food-contact surfaces.

How it fits your monitoring

ATP gives a same-day trend between laboratory culture (HPC/CFU) and endotoxin results. A rising RLU trend triggers sanitisation of carbon beds, a membrane CIP or a loop disinfection before quality drifts.

Service options

One-off site audit with a sampling map and report, or scheduled ATP testing as part of an AMC, with baseline and action levels set for each sampling point.

Design data we need

System layout and sampling points, water use (dialysis, food, process, drinking), current lab results and cleaning or disinfection schedule.

Included / excluded

Included: sampling plan, on-site ATP readings, RLU trend report and recommendations. Excluded unless written: accredited laboratory culture and endotoxin testing fees, remedial cleaning works (quoted separately).

Specifications

ParameterTypical
MeasurementATP in relative light units (RLU)
Sample typesWater samples and surface swabs
Result timeTypical under 1 minute per test
InstrumentHandheld luminometer with data storage and PC export
PowerRechargeable or replaceable batteries
Operating temperatureTypical 5 to 40 °C
UseTrend monitoring of RO, cooling tower, dialysis and potable systems

Typical values. Final specifications depend on feed water analysis and site requirements.

Talk to us